background
SIL2 TUV Certified-Safety Controller:TK-E50
Features

Safety RTU serves as the logic solver in a Safety Instrumented System (SIS) acc. to IEC 61511, it controls complex and often critical processes in real time - executing application programs that receiving field sensor signals, performing calculations for continuous process control and generating control signals to actuator.RockE50-2.png

Features

The main features of TK-E50 Safety RTU are as follows:

l  Facilitates differing fault tolerant topologies - 1oo1 or 1oo2

l  Flexible modular construction using individual modules to build a system

l  Operates as a standalone system or part of a larger distributed network

l  IEC 61508 certified, reviewed and approved by TÜV Rheinland

l  Scalable I/O module expansion

l  I/O module replacement without system interruption for dual-redundant configuration

l  Supports industry standard safety communication protocol of ESCB

 

Non-safety features of TK-E50 Safety RTU:

l  Connection with HMI Software via Ethernet connection using standard Modbus TCP protocol.

l  Connect to third-party I/O devices via RS-485 serial connection using standard Modbus RTU protocol and act as Modbus master.


Expansion Capability

TK-E50 system is comprised of safety engineer station and safety control station.

l  Safety Engineer Station (SES)

SES is personal computer in which two software tools: FlexiSafe Workbench and TK-ESet, are installed. They are used by engineers to develop application programs and configure the system

 

l  Safety Control Station (SCS)

SCS is the controller which is comprised of a Safety Processing Unit (SPU) and a Safety Extension Unit (SEU). SPU is the basic unit of SCS. SEU is optional for SCS and is used to increase the number of I/O channels.

 

A SPU supports up to 96 I/O points and a SEU supports up to 128 I/O points (including DI, AI and DO_8 in total). The total I/O point number for a SCS is 480 maximum.


List of TK-E50 Modules & Software Tools

Category

Type

Description

Safety   related?

Processor Module

FSC5501

Processor   Module (2 Ethernet, 1 USB)

Yes

Power Supply Module

FSC5201

Power   Supply Module (24VDC input, 5VDC output)

Yes

Communication Module

FSC5301

Communication   Module with 3 RS485 port

No

I/O Module

FSC5101

Analog   Input Module, with 8 Analog Input Channels (4-20mA)

Yes

FSC5112

Digital Input Module,   with 8 Digital Input Channels

Yes

FSC5133

Digital Output   Module, with 8 Digital Output Channels

Yes

FSC5103

Analog   Input Module, with 16 Analog Input Channels (4-20mA)

Yes

FSC5114

Digital   Input Module, with 16 Digital Input Channels

Yes

FSC5113

Digital   Input Module, with 16 Digital Input Channels(SOE_16)

Yes

Backplane

FSC5801

Main Backplane

Yes

FSC5802

Extended Backplane

Yes

Terminal   Module

FSC5811

Analog Input Terminal Module for single AI_8 module

Yes

FSC5821

Analog Input Terminal   Module for dual-redundant AI_8 module

Yes

FSC5831

Analog Input Terminal Module for single AI_16 module

Yes

FSC5841

Analog Input   Terminal Module for dual-redundant AI_16 module

Yes

FSC5812

Digital Input Terminal Module for single DI_8 module

Yes

FSC5822

Digital Input Terminal Module for dual-redundant DI_8 module

Yes

FSC5832

Digital Input Terminal Module for single DI_16   module

Yes

FSC5842

Digital Input Terminal Module for dual-redundant   DI_16 module

Yes

FSC5813

Digital Output Terminal   Module for single DO_8 module

Yes

FSC5823

Digital Output Terminal Module for dual-redundant DO_8 module

Yes

FSC5803

Communication   Terminal Module

No

Configuration SW tool

FlexiSafe Workbench

Offline software tool   used for developing application programs and configuring the Safety Control   Station.

T3 tool

Diagnostic SW tool

RockESet

Software tool used   for displaying diagnosis information, monitoring the system and non-safety   configurations

No

SOE SW   tool

SOEviewer

Software   tool used for reading and displaying SOE data

No


Technical Parameter